Skip to content
Home/Cultivation library/Coco & irrigation
Coco & irrigation · 3 MIN READ

What to Check When Part of a Room Misses an Irrigation

CropSalt cultivation guide

Start at the plants, not the controller. The tank can hold the right CropSalt mix and the controller can say the irrigation ran, but neither tells you what reached the pots. Find the dry pots, then trace back: one pot points to its outlet or tube, one row or zone points to that line, and the whole room points to the schedule, reservoir or pump.

Find the pattern

What's dryCheck first
One potIts outlet: displaced, blocked or disconnected tube
One row or zoneThat zone's valve, filter, line and pressure
Far end of a linePressure and flow: too many outlets running at once, undersized line, dirty filter
Whole roomSchedule, reservoir level, pump and main valves

Look at the pot surface too. A dry patch on one side means water is coming out but not covering the pot.

Prove it with a catch test

Catch solution from the suspect outlet and a working one for the same amount of time. When a whole zone is weak, compare near, middle and far outlets. The rating printed on an emitter doesn't replace this check.

Repair the delivery problem

  • One weak outlet: clean or replace it, reconnect the tube, and repeat the catch test.
  • Weak zone: check the filter screen and seals, and whether water is bypassing the screen. Material can also form in the lines past the filter.
  • Pressure but no flow: check the path after the pump before you call the pump dead. Is the valve actually opening?
  • Too many outlets: adding lines can spread the available flow too thin. Fix the zoning or supply before adding runtime.

Don't just lengthen the timer. It won't clear a blocked outlet and it overwaters the pots that were already getting the right amount.

Handle the pots that went dry

Get them back on the system first. Dry coco rewets unevenly, so make sure the next feed wets the whole pot, not just a channel down one side. Keep those pots' readings separate from the rest of the room: a pot that missed feeds can read very differently, and a runoff reading stuck at the meter's maximum is the meter's limit, not the real EC. Once they're back on normal feeds, compare feed and last-10% runoff EC and pH.

Use the room history as an early warning

We use Govee H5179 sensors to watch temperature and humidity trends. In our rooms, watering often produces a recognizable humidity spike. If that spike is missing, we check the schedule, reservoir, pump and valves. More in How we use Govee sensors.

The spike is a room-level clue. A partial failure can still happen while the rest of the room produces its normal spike, so walk the room and check for dry pots too.

Confirm the repair at the plants

Repeat the timed outlet comparison and watch the affected pots through a full irrigation. They should wet evenly and drain like their neighbors. If plants still look different, test their feed and runoff individually instead of relying on pooled bench drainage.

Room changes can shift water use even when the hardware works. If heat or humidity changed, run the numbers through our VPD calculator.

YOUR GARDEN. YOUR READINGS.

Need help applying this?

Tell us what is happening in your garden so we can help with the problem you are trying to solve.

Talk to us
KEEP GROWING

More on coco & irrigation.

All 73 guides